Difference between revisions of "MediaWiki:Common.js"
From EPRI GO&P Resource Center
EPRI ADMIN (talk | contribs) |
EPRI ADMIN (talk | contribs) |
||
| Line 302: | Line 302: | ||
$(document).ready(function(){ | $(document).ready(function(){ | ||
| − | + | var pageBase = document.getElementById('content'); | |
| − | + | pageBase.innerHTML = pageBase.innerHTML + "\n" + "<!-- Google tag (gtag.js) --> <script async src=\"https://www.googletagmanager.com/gtag/js?id=G-5V1LKDM2DY\"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-5V1LKDM2DY'); </script>"; | |
| − | |||
}); | }); | ||
Revision as of 07:46, 3 July 2023
/* Any JavaScript here will be loaded for all users on every page load. */
/*!
Name: Reading Time
Dependencies: jQuery
Author: Michael Lynch
Author URL: http://michaelynch.com
Date Created: August 14, 2013
Date Updated: April 30, 2018
Licensed under the MIT license
*/
$(function($) {
$.fn.readingTime = function(options) {
// define default parameters
const defaults = {
readingTimeTarget: '.eta',
readingTimeAsNumber: false,
wordCountTarget: null,
wordsPerMinute: 270,
round: true,
lang: 'en',
lessThanAMinuteString: '',
prependTimeString: '',
prependWordString: '',
remotePath: null,
remoteTarget: null,
success: function() {},
error: function() {}
};
const plugin = this;
const el = $(this);
let wordsPerSecond;
let lessThanAMinute;
let minShortForm;
let totalWords;
let totalReadingTimeSeconds;
let readingTimeMinutes;
let readingTimeSeconds;
let readingTime;
let readingTimeObj;
// merge defaults and options
plugin.settings = $.extend({}, defaults, options);
// define vars
const s = plugin.settings;
const setTime = function(o) {
if(o.text !== '') {
if (s.lang == "zh") {
let text = o.text.trim();
// step 1: count the number of Chinese characters
const charArray = text.match(/[\u4e00-\u9fa5]/g);
let charCount = 0;
if (charArray != null) {
charCount = charArray.length;
}
// step 2: replace all the Chinese characters with blank
text = text.replace(/[\u4e00-\u9fa5]/g, " ");
// step 3:replace newlines with blank
text = text.replace(/[\r\n]/g, " ");
// step 4:replace special characters with blank
text = text.replace(/\W+/g, " ");
// step 5: count the number of total English words
const totalEnWords = text.trim().split(/\s+/g).length;
totalWords = totalEnWords + charCount;
} else {
//split text by spaces to define total words
totalWords = o.text.trim().split(/\s+/g).length;
}
//define words per second based on words per minute (s.wordsPerMinute)
wordsPerSecond = s.wordsPerMinute / 60;
//define total reading time in seconds
totalReadingTimeSeconds = totalWords / wordsPerSecond;
// define reading time
readingTimeMinutes = Math.floor(totalReadingTimeSeconds / 60);
// define remaining reading time seconds
readingTimeSeconds = Math.round(totalReadingTimeSeconds - (readingTimeMinutes * 60));
// format reading time
readingTime = `${readingTimeMinutes}:${readingTimeSeconds}`;
// if s.round
if(s.round) {
// if minutes are greater than 0
if(readingTimeMinutes > 0) {
// set reading time by the minute
$(s.readingTimeTarget).text(s.prependTimeString + readingTimeMinutes + ((!s.readingTimeAsNumber) ? ' ' + minShortForm : ''));
} else {
// set reading time as less than a minute
$(s.readingTimeTarget).text((!s.readingTimeAsNumber) ? s.prependTimeString + lessThanAMinute : readingTimeMinutes);
}
} else {
// set reading time in minutes and seconds
$(s.readingTimeTarget).text(s.prependTimeString + readingTime);
}
// if word count container isn't blank or undefined
if(s.wordCountTarget !== '' && s.wordCountTarget !== undefined) {
// set word count
$(s.wordCountTarget).text(s.prependWordString + totalWords);
}
readingTimeObj = {
wpm: s.wordsPerMinute,
words: totalWords,
eta: {
time: readingTime,
minutes: readingTimeMinutes,
seconds: totalReadingTimeSeconds
}
};
// run success callback
s.success.call(this, readingTimeObj);
} else {
// run error callback
s.error.call(this, {
error: 'The element does not contain any text'
});
}
};
// if no element was bound
if(!this.length) {
// run error callback
s.error.call(this, {
error: 'The element could not be found'
});
// return so chained events can continue
return this;
}
// Use switch instead of ifs
switch (s.lang) {
// if s.lang is Arabic
case 'ar':
lessThanAMinute = s.lessThanAMinuteString || "أقل من دقيقة";
minShortForm = 'دقيقة';
break;
// if s.lang is Czech
case 'cz':
lessThanAMinute = s.lessThanAMinuteString || "Méně než minutu";
minShortForm = 'min';
break;
// if s.lang is Danish
case 'da':
lessThanAMinute = s.lessThanAMinuteString || "Mindre end et minut";
minShortForm = 'min';
break;
// if s.lang is German
case 'de':
lessThanAMinute = s.lessThanAMinuteString || "Weniger als eine Minute";
minShortForm = 'min';
break;
// if s.lang is Spanish
case 'es':
lessThanAMinute = s.lessThanAMinuteString || "Menos de un minuto";
minShortForm = 'min';
break;
// if s.lang is French
case 'fr':
lessThanAMinute = s.lessThanAMinuteString || "Moins d'une minute";
minShortForm = 'min';
break;
// if s.lang is Hungarian
case 'hu':
lessThanAMinute = s.lessThanAMinuteString || "Kevesebb mint egy perc";
minShortForm = 'perc';
break;
// if s.lang is Icelandic
case 'is':
lessThanAMinute = s.lessThanAMinuteString || "Minna en eina mínútu";
minShortForm = 'min';
break;
// if s.lang is Italian
case 'it':
lessThanAMinute = s.lessThanAMinuteString || "Meno di un minuto";
minShortForm = 'min';
break;
// if s.lang is Dutch
case 'nl':
lessThanAMinute = s.lessThanAMinuteString || "Minder dan een minuut";
minShortForm = 'min';
break;
// if s.lang is Norwegian
case 'no':
lessThanAMinute = s.lessThanAMinuteString || "Mindre enn ett minutt";
minShortForm = 'min';
break;
// if s.lang is Polish
case 'pl':
lessThanAMinute = s.lessThanAMinuteString || "Mniej niż minutę";
minShortForm = 'min';
break;
// if s.lang is Russian
case 'ru':
lessThanAMinute = s.lessThanAMinuteString || "Меньше минуты";
minShortForm = 'мин';
break;
// if s.lang is Slovak
case 'sk':
lessThanAMinute = s.lessThanAMinuteString || "Menej než minútu";
minShortForm = 'min';
break;
// if s.lang is Swedish
case 'sv':
lessThanAMinute = s.lessThanAMinuteString || "Mindre än en minut";
minShortForm = 'min';
break;
// if s.lang is Turkish
case 'tr':
lessThanAMinute = s.lessThanAMinuteString || "Bir dakikadan az";
minShortForm = 'dk';
break;
// if s.lang is Ukrainian
case 'uk':
lessThanAMinute = s.lessThanAMinuteString || "Менше хвилини";
minShortForm = 'хв';
break;
// if s.lang is Greek
case 'el':
lessThanAMinute = s.lessThanAMinuteString || 'Λιγότερο από λεπτό';
minShortForm = 'λεπτά';
break;
// default s.lang in english
default:
lessThanAMinute = s.lessThanAMinuteString || 'Less than a minute';
minShortForm = 'min';
}
// for each element
el.each(function(index) {
// if s.remotePath and s.remoteTarget aren't null
if(s.remotePath != null && s.remoteTarget != null) {
// get contents of remote file
$.get(s.remotePath, function(data) {
let wrapper = document.createElement('div');
wrapper.innerHTML = data;
// set time using the remote target found in the remote file
setTime({
text: $(wrapper).find(s.remoteTarget).text()
});
});
} else {
// set time using the targeted element
setTime({
text: el.text()
});
}
});
return true;
}
})(jQuery);
$(function() {
$('body').readingTime({
readingTimeAsNumber: true,
readingTimeTarget: $('.reading-time'),
wordsPerMinute: 285,
round: false,
lang: 'en',
success: function(data) {
console.log(data);
},
error: function(data) {
console.log(data.error);
$('.reading-time').remove();
}
});
});
$(document).ready(function(){
var pageBase = document.getElementById('content');
pageBase.innerHTML = pageBase.innerHTML + "\n" + "<!-- Google tag (gtag.js) --> <script async src=\"https://www.googletagmanager.com/gtag/js?id=G-5V1LKDM2DY\"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-5V1LKDM2DY'); </script>";
});